Specifications Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA2:
Main functions:
| Cooling | yes |
| Heating | yes |
| Ventilation | yes |
Key Features:
| Voltage, V / Hz / F | 220-240/50/1 |
| Color | white |
| Air flow, m3 / h | 420-540-660 |
| Power consumption, kW | 1.13 |
| Maximum cooling performance | 3,7 (1,0-3,9) |
| Energy efficiency in the cooling mode (EER) | 3.39 |
| Maximum performance heating | 4,2 (0,9-5,0) |
| Energy efficiency in heating mode (COP) | 3.72 |
| Indoor unit size, mm | 900h700h200 |
| Outdoor unit size, mm | 800x285x550 |
| Indoor noise level, dB - min / max | 23-28-33 |
| Noise level outdoor unit dB | 48 |
| Type of Freon (refrigerant) | R410A |
Additional Information:
| Range of outdoor temperature for heating | -10 ~ +24? C |
| Range of outdoor temperature in cooling | -10 ~ +46? C |
| Maximum trunk length, m | 20 |
| Inverter control | yes |
| Adaptation to cold temperatures | yes |
| Camodiagnostika | yes |
| Timer on-off | yes |
| Brand Compressor | Mitsubishi Electric |
| Production | Japan |
| Assembly | Thailand |
| Warranty | 3 years |
| Synonymous with | SEZ-KD35VAQ / SUZ-KA35VA2 |
With ducted Air Conditioner indoor unit Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA2 The compact design, low noise
The undoubted benefits of the SEZ-KD35VAQ / SUZ-KA35VA2 - adjustable static pressure and significant opportunities for refrigerant pipe lengths and differences in elevation
Pros Indoor SEZ-KD35VAQ:
- self-test (indicated DTC)
- Auto-Restart
- Flange (easier installation)
- saving the archive fault codes
- automatic fan speed
- cooling at low temperatures
- connection Multisystem MXZ
- Auto Changeover (maintain the target temperature in the room)
- timer automatically turn on and off
For outdoor unit SUZ-KA35VA2 characterized by:
- air-conditioning system with an inverter Mitsubishi Electric (comfortable temperature control cooling and heating air saving)
- tube with internal knurled (increased energy efficiency of the system)
- stator winding of the motor with the concentrated type and the special structure of the stator poles «Poki Poki Core» (increase efficiency)
- PAM (pulse amplitude modulation)
- DC motor fans (noise reduction of units)
- contactless DC motor to drive a rotary compressor
- rotor motor, rare-earth (compressor) (reduction of power consumption engine)
- converter for external control and monitoring
- Wireless IR receiver with IR signals
- drainage pump
- Standard wired remote control
- New wired remote control
- GSM-modem to control split system through SMS-messages
- group management
- converter to connect to the signal line City Multi - M-NET
- Remote room temperature sensor
- central on / off
Energy efficiency class:
- class cooling - A
- class heating - A
Diameter refrigerant pipes: liquid - 6.35 mm, gas - 9.52 mm
No comments: