4.15.2013

The outdoor unit (heat pump) Daikin RXYQ10P9 VRV III

Daikin RXYQ10P9

Specifications Daikin RXYQ10P9:

Main functions:

Coolingyes
Heatingyes

Key Features:

Voltage, V / Hz / F380-415/50/3
Colorwhite
Room size, sq m300
Power consumption, kW7,42-7,70
Maximum cooling performance28.0
Energy efficiency in the cooling mode (EER)3.77
Maximum performance heating31.5
Energy efficiency in heating mode (COP)4.09
Outdoor unit size, mm1680x930x765
Noise level outdoor unit dB58
Type of Freon (refrigerant)R-410A

Additional Information:

Brand CompressorDaikin
ProductionJapan
AssemblyBelgium
Warranty3 years
Synonymous withRXYQ10P9

Outdoor unit with minimal footprint Daikin RXYQ10P9 has:

  • Modular configuration of outdoor units
  • simple installation
  • possibility of using the zoom mode apparent cooling (energy efficiency of the system and the level of comfort, and two variants of modes: fixed and stselevoy evaporator temperature)
  • no special foundations (placing the outdoor unit on 4 supports at the corners)
  • the most efficient and ozone-friendly refrigerant R-410A
  • the ability to automatically restart (when temporary power failure)
  • Inverter capacity control
  • The compact outdoor unit (saves space)
  • The ability to integrate solutions in a single system to control the temperature in the room, providing fresh air, use air curtains)
  • possible use in cold regions (lower limit of atmospheric temperature when operating in heating mode, -25 ° C)
  • ability to reduce the noise level of outdoor units by 9 dB in the night period (reduced energy consumption)
  • ability to work in case of failure of one of the compressors
  • high seasonal energy efficiency ratio of the system
  • advanced control and monitoring (display value of any parameter, automation perform most functions)
  • longest pipeline route coolant (up to 1000 m)
  • a phased commissioning of the system
  • possibility of automatic refueling system with refrigerant with automatic refrigerant charging amount
  • energy efficiency in cooling and heating mode
  • possibility of automatic refueling system with refrigerant with automatic refrigerant charging amount
  • ability height difference between indoor units up to 30 m (extension applications)
  • low noise level of outdoor units (from 54 dBA)
  • longest pipeline route coolant (up to 1000 m)
  • the possibility of installing the outdoor unit in the room (high external static pressure fan)
  • wide range of models of outdoor and indoor units
  • ability height difference between indoor units up to 30 m
  • the highest number of indoor units in the same system
  • two stages of the night mode (up to 50dBA and 45dBA respectively)
  • ability to limit the power consumption (in terms of lack of electricity)
  • system reliability

Number of outdoor units - 1
Maximum number of connectable indoor units - 21

Pipe diameters:

  • liquid - 9.52 mm
  • gas - 22.2 mm