6.05.2013

Sanyo SAP-KCRV186GHDX

Sanyo SAP-KCRV186GHDX

Specifications Sanyo SAP-KCRV186GHDX:

Main functions:

Coolingyes
Heatingyes
Filteringyes
Ionizationyes
UV filteryes
Dehumidificationyes
Ventilationyes

Key Features:

Room size, sq m55
Maximum cooling performance5.15
Maximum performance heating5.70
Indoor unit size, mm298x1065x218

Additional Information:

Inverter controlyes
Adaptation to cold temperaturesyes
Automatic restartyes
Timer on-offyes
Remote controlyes

Automatic switching between heating and cooling

Comfortable

The function of air purification

Step-function power reduction at night

Filter to protect against mold

Work on high power

Integrated temperature sensor Remocon

Cleaning the LED

Washable panel

Memory optimal temperature

Self-diagnosis

24 hour programmable timer

Quiet operation

Washable air-filter

Ionic air purification

1, 2, 3, 4, 5 hour off timer

Washable antibacterial apatite filter

Automatic control valve and guide

Automatic fan operation

Microprocessor control

The address switch (on the remote)

Automatic restart

Thawing at 15 degrees

A three-dimensional air flow

SANYO air conditioner blinds are controlled by four independent motors, so that you get the opportunity to own, use the remote control to choose the direction of air flow.

Ability to work in cooling mode at low temperatures (down to -15 º C)

Speed control of the fan and compressor in the outdoor unit makes it possible to work SANYO air conditioner in cooling mode, in cold temperatures outside air (up to -15 º C)

Non-stop defrosting of outdoor unit

Thanks to circumvent the basic circuit diagram for Freon thaw in conditioners SANYO, it is possible to activate the defrost by running the heating mode, which allows to maintain the heat in the room.

Multi-function IR d / y

The console has a lot of new user-friendly features, such as built-in temperature sensor, a mute button LEDs, high-power button, button silent operation, etc.

LED photocatalytic filter

Resettable sterilizing filter detects allergens, germs and bacteria with an optical sensor and destroy their LED light.

Apatite filter

Calcium phosphate (apatite) - very effective at filtering pollen, smoke, dust, bacteria and common, three-layer filter made using apatite divided by dust (electrically charged fibers), deodorant (with activated carbon and photocatalytic deodorizer), antibacterial ceramic and photocatalytic.

Air ionization

Negative ions help to create an atmosphere in the room as in a forest near the waterfall.

Ultra Quiet Mode Operation 22 dB.

The noise level is 22 dB. is between a whisper and rustle of leaves, at that noise at work and leisure can be carried out with maximum efficiency.

Use of refrigerant R-410A

HFC refrigerant based entirely harmless to the ozone layerandnbsp;

Economical night mode

At night, when the appropriate mode, Air Conditioner SANYO, automatically twice with an interval of 30 minutes, increases / decreases the power for heating / cooling, 2/1 º C.

Automatic restart

In homes where there are frequent disruptions and fluctuations in the power supply, this feature is indispensable, because it is thanks to it you will not need to include every time and adjust Air Conditioner, because his work will be resumed automatically after the resumption of power

3-speed fan

Fan speed control is a microprocessor that automatically adjusts it depending on the mode used.

Sheltered from the mold, the filter

Treated with special chemicals filter prevents mold and bacteria.

Maintenance indicators

When the air conditioner filter is too clogged to perform their functions, you will be informed about this special light.

Detachable Front Panel

To be able to wash, the front panel can be easily removed and then back set.

Even distribution of air flow

The cyclic variation of the angle valve outlet, true directs the air flow throughout the room.

Child Lock

To prevent accidental changes to the air conditioner from young children, you can use the automatic locking.

Self-diagnosis

The built-in air conditioner SANYO microprocessor automatically finding indicates failure in the indoor unit, in case of malfunctions.

Energy-saving inverter technology

Superweak work inverter compressor maintains the set temperature after the Air Conditioner dialed her.

Timer

Turning on and off the air conditioner at a preset time every day and combined in the next 24 hours.

No comments:

Post a Comment