Technical characteristics Hitachi RAS-10BH5/RAC-10BH5:
Main functions:
Cooling | yes |
Heating | yes |
Filtering | yes |
Dehumidification | yes |
Ventilation | yes |
Key Features:
Room size, sq m | 30 |
Power consumption, kW | 0.97 |
Maximum cooling performance | 2.6 |
Maximum performance heating | 3.0 |
Indoor unit size, mm | 280h780h220 |
Outdoor unit size, mm | 500h775h300 |
Indoor noise level, dB - min / max | 28/39 |
Type of Freon (refrigerant) | R410A |
Additional Information:
Inverter control | no |
Adaptation to cold temperatures | to -7 |
Automatic restart | yes |
Timer on-off | yes |
Remote control | yes |
Brand Compressor | Hitachi |
Production | China |
Warranty | 3 years |
Additionally | Rotary compressor |
AIR HITACHI:
Air quality and energy conservation
In todayand#39;s world demands a person to indoor environment is growing. Air conditioner took a firm place in our life and its main task - to maintain a comfortable temperature in the house. But is that enough for the full comfort? Air Conditioner Company HITACHI Series PREMIUM able not just to cool the air in the room, but also clean it from all kinds of impurities, to control humidity drained, aerated ionized moisture and automatically clean the filters. Air conditioner has a function to prevent the formation of mold, and the internal parts are made of stainless steel, which prevents bacteria and mold build up inside the air conditioner. In addition, it is a powerful and energy-efficient system, equipped with leading inverter technology in Japan and has a simple and elegant design. HITACHI air conditioners companies create a healthy and comfortable environment.
STAINLESS CLEAN - Really clean air
Due to the interior of the air conditioner, which are made of stainless steel, Air Conditioner remains clean and allows you to clean the air at any point in the system.
Air channel in stainless steel
The rear wall of the air channel for ventilyatrom made of stainless steel. Use of the material prevents plaque formation and the function of disinfection.
Air damper is made of stainless steel
To manufacture the choke is used stainless material that protects against the formation of plaque and performing a function of disinfection, which allows for a clean air outlet.
Fan with a silver-ion-coated
The fan unit is in the room, covered with a metal containing silver ions. This material prevents the formation of plaque and the function of decontamination, which preserves the surface of the fan clean.
Heat exchanger with titanium coating
Coating titanium catalyst deposited on the surface of the heat exchanger, allows to eliminate odors. This same material prevents the formation of plaque, the function of decontamination and inhibits the growth of fungi.
Microcellular filter made of stainless steel
Filter made of stainless material has several advantages compared to conventional polyurethane filter. It is much more durable and resistant to dirt greasy coating, and easy to clean. By coating of titanium oxide, it has the effect of decontamination.
Node auto filter
Node auto filter cleans dust, captured microcellular stainless steel filter into a container to collect dust. With this air conditioner filter is in constant state of cleanliness.
Plasma cleaning air
Plasma electrode emits negative ions that surround the particles of dirt and trapped microcellular filter made of stainless steel. Different models use one or two electrodes.
Freshen the air by means of ionized water!
Ionized moisture nanoscale not only has the effect of removing odors, but also destroys airborne bacteria, viruses and fungi
GENERATOR IONIZED MOISTURE
Air conditioner equipped with ion generator, which produces nanoparticles moisture. This ionized moisture surrounds and kills bacteria, viruses and fungi by up to 99.99% * and decomposes and removes odors.
* Check for bacteria, which were released into the test container volume of 1 m3. After some air circulation and make ionized water was measured by the number of bacteria, viruses and fungi in the air. After 40 minutes, 99.99% of the bacteria were killed. Tests were carried out the Research Center for Environment Shibasaburo (Kitasato Researche Center of Environmental Sciences). Report № KK18_0040, KS18_0214, KS18_0215
Unique effect of disinfection and odor
Nanoparticles ionized water decompose and eliminate kitchen odors, cigarette smoke, pet odors, and even chronic odors clothes or curtains.
Ionization mechanism of moisture
Water is formed inside the air conditioner out of the air in the room, on the principle of condensation on a glass of ice water. Condensed water is ionized and is served in the room. No need to fill with water. Radiated thermoelectric cooler portion of hot air cools the air flow in the room.
Moisture control
In the andquot;Automatic drainageandquot; and andquot;cooling with dehumidificationandquot;
Besides the temperature in some modes conditioner controls the level of humidity. Control range is 40-70% in 5% increments.
FRESH AIR: integrated ventilation system Air Exchanger
In a limited space (with windows and doors closed) oxygen in the air decreases rapidly, the air becomes stale. Unlike other air conditioners, ventilation Air Exchanger from Hitachi takes fresh air from outside, filters it, effectively trapping pollutants, such as carbon dioxide, formaldehyde, odors and bacteria, and then delivers it to the room.
Self-cleaning function
Management of self-cleaning is performed with the remote control. This function uses the automatic ejection of air out to remove moisture and heat exchanging surface is completely dry the indoor unit. Dry heat exchanger and clean the inner surface of the air conditioner to avoid unpleasant odors and extends the life of the air conditioner.
Fresh air in sleep
If you include a supply of fresh air in sleep in the summer, the sensor monitors the temperature in the room, the humidity and temperature of the outside air even after turning off the air conditioner and provides fresh air into the room from the street, when the outdoor temperature is lower than the temperature in the room. As the concentration of CO2 does not increase, you can always enjoy the freshness of the morning!
The highest energy efficiency class
Under the new EU directive identifies seven levels of energy efficiency from A to G. Series Air Exchanger assigned the highest energy efficiency class - Class A.
Handy remote control
For user convenience, the size of the control buttons and output increased. Since all the buttons displayed on the cover of the remote control, to control air exchange modes, the supply of fresh air into the sleep mode and self-cleaning is easy.
Mode exhaust and fresh air
Thanks to the air, the air from the room is effectively removed and replaced with fresh. Mode exhaust and fresh air can be used as a cooling / heating, or just for ventilation. You can select with the remote control one of six modes: the mode of extraction (Hi-Me-Lo) to the fresh air intake (Hi-Me-Lo). In automatic mode, ventilation, air quality sensor analyzes the amount of O2 and CO2 in the room and selects the desired mode - supply and exhaust ventilation.
Work up to 20 degrees
In heating mode, many models HITACHI air conditioners can operate at ambient temperatures down to -20 ° C. This is achieved through the use of inverter technology ALL DC Inverter compressor and special design.
Low noise level: 20 dB
Through the use of advanced technologies HITACHI noise indoor unit at the minimum speed is only 20 dB. This mode is useful when you want to maintain the achieved temperature or at night. The system uses less energy than at higher speeds, allowing you to save money. Just press the fan speed controller to select the minimum speed, or select
automatic.
The air quality sensor
The air quality sensor detects the presence of smoke in the air, aerosols, (insecticides, etc.), blood alcohol and other substances. For example, the models of the series Air Exchanger in automatic ventilation sensor analyzes the state of the air, and enters supply or exhaust ventilation. In models of series PREMIUM XH air quality control can implemented when selecting this function with the remote control model. In this case, the remote may also set the level of sensitivity of the sensor.
Sleep timer
Allows you to set the air conditioner to turn off the timer. In this case, prior to shutdown the fan runs at minimum speed, creating favorable conditions for a good sleep.
Airflow control
A model of RAS-30CH7 is possible to automatically control the air flow in two directions. With horizontal blinds to regulation of air flow to the left and right, and with the help of vertical blinds - up and down.
Consistent inverter control current All-DC Inverter
Inverter technology ALL-DC INVERTER from HITACHI provides lavnost reach the required temperature and high energy efficiency when air conditioners. In contrast to the control circuit has traditionally compressor operation (andquot;on / offandquot;), nvertornaya technology allows infinitely variable rpm Compressor, and thus the cooling capacity air conditioner. result, we get a more accurate maintenance of the required temperature, and increased resource nergoeffektivnost compressor for less odd cycles andquot;Start / Stopandquot;. HITACHI compressors are equipped with DC motor with permanent magnets. andquot; They are 10% more efficient than conventional AC compressors. Thus completely eliminating annoying andquot;buzzandquot; caused by electromagnetic waves of AC motors.
New dual rotary compressor
New dual rotary compressor HITACHI has less vibration and higher efficiency compared to conventional rotary compressors. Two cylinders provide a well-balanced rotation, in contrast to conventional compressors with one cylinder. Thus, significantly reduces noise and vibration. The motion of two independent cylinders improves the compressor, making it more efficient.
Nano Titanium Technology
NANO TITANIUM COATING FOR DIFFERENT TYPES OF FILTERS
HITACHI new air conditioners use Nano Titanium filter, consisting of antibacterial nanoparticles. Ultramodern technology Nano Titanium, which pioneered the use of the company HITACHI, with facility of up to 5 nm
(Nanometers) - (5/1, 000 000 mm). For example, the diameter of a human hair is 50,000 nm, the size of the virus staph - 1000 nm, influenzavirus - 50-100 nm, cigarette smoke - 10-50 nm. With the latest technology HITACHI, Nano Titanium filter can trap particles 10,000 times thinner than a human hair, creating for you a healthy and clean air.
FILTER NANO TITANIUM
In the domestic air conditioner HITACHI with integrated ventilation Air Exchanger installed three filters. One filter cleans the incoming air from the street, the other two Nano Titanium filter the air in the room.
UV air purification
Tests conducted by the Japanese laboratory for food testing confirmed the high efficiency LED UV Air Cleaner in the destruction of bacteria, viruses, mold, fungi and other harmful microorganisms. Based on these studies, the lab issued Acknowledgment conclusion number 203061804-001 on 07/29/2003
DISINFECTION UV radiation
In nature, germicidal UV is part of the solar spectrum and provides a balance of microorganisms in the air and on the ground. HITACHI specialists used a method of UV radiation by incorporating the UV lamp to the indoor unit. Intake air passing through the filter is cleaned, and then passes shortwave ultraviolet light disinfection.
The distribution of air flow at 162 degrees
Angle distribution of the air flow is 162 degrees. In addition you can set from the control one of the options of air distribution. This is useful when used in large areas, and allows more flexibility in choosing a location for the installation of the indoor unit. Depending on the installation location and configuration of the room (the center of the room, a corner on the left or right, etc.) A wide range of air flow control.
Jet Flap Flap
Convenience and comfort are increased by the use of flaps JET FLAP, since the flow of cooling air to the ceiling twisted, and when heated - to the floor. Automatically directs the flow of cooling air to the ceiling, providing a more efficient cooling. Tightening the air flow flap down, providing a more efficient heating
Comfortable drainage
Heat recovery system allows you to remove moisture from the air without lowering the temperature in the room. When working in conditions of 40% humidity this mode destroys mites and fungi. Depending on your needs, there are three modes of drying, andquot;Autoandquot;, andquot;Quick Dryandquot;, andquot;defogandquot;.
High COP
According to the directive EC-92/75/EES (July 2004), all air conditioners should be provided with the designation of the category of energy efficiency. In line with its energy-saving features, air conditioners classified in descending order from andquot;Aandquot; to the «G». Thanks to Hitachi DC-Inverter, air conditioners Hitachi assigned the highest energy class - Class A.
No comments:
Post a Comment